(40.18 € No tax)
Danfoss PVLP shock and anti-cavitation valves for ports A and B of PVG 32 sections, with fixed setting between 80 and 320 bar.
Danfoss PVLP valves for PVG 32 proportional directional valves. They combine two functions: shock relief, which limits pressure peaks on port A or B, and anti-cavitation, which lets oil in from the return when the port is under vacuum. They fit PVB sections with facilities for shock valves.
The pressure is factory set and given by the last digits of the code: 157B2080 = 80 bar, 157B2125 = 125 bar, and so on up to 157B2320 = 320 bar (with 175, 190, 210 and 280 bar in between). There are also 157B1175 and 157B1190 (175 and 190 bar) and PVLP of 210 bar and 280 bar (157B1210 and 157B1280).
Choose the same pressure as the valve being replaced or the one shown on the machine's circuit diagram.
Source: Danfoss PVG 32 technical catalogue, version BC00000038en-US0710, March 2016.