One-way pressure-compensated flow control valve, 0 to 2.5 l/min, for NG6 (CETOP 3) subplate mounting. Tognella FT 288/5-03-CH.
Pressure-compensated flow control valve from Tognella, FT 288/5 series, for NG6 (CETOP 3) plate mounting. Compensated means it holds the set flow even when the working pressure changes, so the actuator moves at the same speed with more or less load.
It is one-way: it controls one direction and the return flows freely. The range is 0 to 2.5 l/min, intended for very slow, steady feeds.
It fits on a subplate or in the CETOP 3 stack. Before ordering, check the controlled flow direction and that the flow of the movement fits within this range.