Subcategories

  • Directional valves

    Directional valves send the oil to one side or the other of the circuit: they extend and retract a cylinder, turn a motor one way or the other, or stop the movement.

    They are arranged by size and mounting type:

    You will find Duplomatic, Argo-Hytos, Hydac and NEM solenoid valves, with solenoid, manual or pilot operation. Size (NG) goes with flow: the larger the NG, the more flow the valve passes.

    To replace a valve, the code on the plate gives the size, the spool (what the valve does in each position) and the coil voltage. Search for that code. Without a code, you need the size or thread, the spool symbol, the coil voltage and current type (for example 24 V DC) and whether it has a manual override. Replacement coils are under Coils.

    Technical guide: How to choose a hydraulic valve

  • Proportional valves

    Proportional valves: the spool position, pressure or flow varies continuously with the electrical signal, instead of just opening and closing.

    They give smooth movements, starts and stops without shocks and remotely adjustable speeds. Arranged into CETOP proportional valves and cartridge proportional valves.

    • Proportional directional valves Duplomatic DSE3, DSE5 and DSPE and Argo-Hytos: control direction and speed;
    • Proportional relief valves (PDE3, PRE): pressure varies with the signal;
    • Proportional pressure reducing valves, modular (MZE, PZME);
    • Proportional flow control valves (QDE3) and NEM and Argo-Hytos proportional cartridges.

    A proportional valve needs control electronics: an amplifier or card that converts the signal (0-10 V, 4-20 mA or from the joystick) into coil current. Some valves have on-board electronics (OBE). See Electronics and joysticks.

    To choose: size or cavity, function, flow and pressure, coil voltage, signal type and whether the electronics are on-board or external. Proportional valves need clean oil: check the filtration recommended by the manufacturer.

    Technical guide: How to choose a hydraulic valve

  • Relief valves

    A pressure relief valve protects the circuit: when pressure reaches the set value, it opens and sends the oil to tank. Every hydraulic power unit has one.

    Without it, an overload can burst hoses, pumps or cylinders.

    Direct-acting valves react quickly and are simple; pilot-operated valves handle larger flows with less pressure variation. Anti-shock valves (VAU) protect hydraulic motors from peaks when braking.

    How to choose: the maximum flow that will pass, the adjustment range (for example 50 to 350 bar; choose a range in which the required pressure sits in the middle), the thread or mounting type and the adjustment method (screw, handwheel or proportional). After fitting, set it with a gauge in the circuit, never blind.

    Technical guide: How to choose a hydraulic valve

  • Check valves

    A check valve lets oil flow in one direction and blocks it in the other. It is used to hold pressure in a branch of the circuit, prevent backflow through the pump or lock a cylinder.

    • CETOP check valves: Duplomatic modular pilot-operated check valves (MVPP, CHM3, CHM5), for stacking under the solenoid valve;
    • In-line check valves: Oleodinamica Marchesini VU, RHD, VUBA and VUBR hose burst valves and VBPSE, VBPDE and VBPSL pilot-operated check valves;
    • Cartridge check valves, NEM and Duplomatic, and Tognella insert check valves.

    A pilot-operated check valve locks the cylinder and only lets oil return when it receives pilot pressure from the other line. It holds a load without creeping down, but does not control the lowering: for overrunning loads, such as cranes and booms, use a counterbalance valve. The double pilot-operated valve (VBPDE) locks both cylinder chambers.

    A hose burst valve closes if the flow suddenly exceeds a value, for example if a hose bursts.

    Choose by flow, maximum pressure and thread; for pilot-operated valves, by pilot ratio.

    Technical guide: How to choose a hydraulic valve

  • Counterbalance valves

    Counterbalance (overcentre) valves hold suspended loads and control the lowering of cylinders and motors subject to overrunning loads, such as cranes and booms.

    They are used on cranes, loader booms, platforms, winches and forestry heads. Arranged into CETOP counterbalance valves, in-line counterbalance valves and cartridge counterbalance valves, from Oleodinamica Marchesini (VBCD), NEM, Argo-Hytos and Eurofluid.

    Unlike a pilot-operated check valve, a counterbalance valve does not let the load drop: it opens gradually according to the pilot pressure and brakes the lowering smoothly. It also protects against overpressure caused by the load.

    • Single-acting (SE): holds one side of the cylinder;
    • Double-acting (DE): holds both sides, for cylinders and motors loaded in both directions;
    • Versions for mounting directly on the cylinder (flanged) or on the motor, which stop the load falling if a hose bursts.

    How to choose: the flow, the setting pressure (normally above the pressure caused by the load), the pilot ratio (for example 3:1 or 4.25:1; lower gives more stability, higher opens more easily) and the thread or mounting. Fit the valve as close as possible to the cylinder.

    Technical guide: How to choose a hydraulic valve

  • Sequence valves

    In-line and modular sequence valves (VSQAPP, VS2C, MSD) for operating a second actuator when pressure reaches the set value. Choose by pressure range and mounting type.

    A sequence valve stays closed until the inlet pressure reaches the set value; only then does it open and let oil through to the second circuit. The typical case is clamping a part and only then working on it: the clamping cylinder extends first and, once it reaches pressure, the second cylinder starts to move.

    Choose by adjustment range, flow, thread or mounting, and check whether an external drain is needed. For lower pressure in one branch of the circuit, see Pressure reducing valves.

    Technical guide: How to choose a hydraulic valve

  • Pressure reducing valves

    Pressure reducing valves: they give one branch of the circuit a lower pressure than the rest, from the same pump. CETOP, in-line and cartridge.

    Arranged into CETOP reducing valves, in-line and cartridge, from Oleodinamica Marchesini (VRP, VRPRL), Duplomatic, Argo-Hytos, NEM and Eurofluid.

    Typical uses: clamping a part with limited force, supplying pilot pressure to other valves or a low pressure control circuit, or protecting a component that cannot take full pressure.

    The difference from a relief valve: the relief valve protects the whole circuit by dumping to tank when pressure exceeds the maximum; the reducing valve holds a lower pressure only downstream of it, while the rest of the circuit stays at normal pressure.

    • CETOP modular reducing valves (MZD, PZM3, Argo-Hytos VRN), stacked under a solenoid valve to limit pressure on that function only;
    • In-line reducing valves, with or without free-return check;
    • Proportional reducing valves (MZE, PZME), controlled by an electrical signal.

    Choose by reduced pressure range, flow and mounting.

    Technical guide: How to choose a hydraulic valve

  • Flow restrictors

    Flow restrictors set the speed of a hydraulic cylinder or motor by narrowing the oil passage. They are the simplest and cheapest way to control flow.

    • CETOP restrictors: Duplomatic modular valves for stacking under the solenoid valve, with meter-in or meter-out control;
    • In-line restrictors: Oleodinamica Marchesini (VRF, VRFU, VRB, VRFB) and Tognella;
    • Cartridge and insert restrictors, for manifolds.

    Two types:

    • One-way: restricts in one direction and allows free flow in the other (it has a built-in check valve). This is the most used: for example, it controls a cylinder lowering and leaves the raising at normal speed;
    • Two-way: restricts in both directions.

    A simple restrictor lets the speed vary with load and oil temperature. If you need constant speed, use a pressure-compensated flow control valve.

    Choose by thread, maximum flow and type of adjustment (fine or normal).

    Technical guide: How to choose a hydraulic valve

  • Flow control valves

    Flow control valves for keeping the speed of hydraulic cylinders and motors constant, even when load or pressure changes.

    Arranged into CETOP flow control valves, in-line flow control valves and cartridge flow control valves, from Oleodinamica Marchesini, Tognella, Duplomatic, NEM, Argo-Hytos and Hydac.

    The difference from a simple restrictor is pressure compensation: a compensated valve holds the set flow even if the downstream pressure changes, so the cylinder always moves at the same speed, loaded or not.

    • 2-way: controls the flow passing through;
    • 3-way (RFP3, VPR3): controls the flow to the actuator and returns the excess to tank, which heats the oil less;
    • Proportional: the flow is controlled by an electrical signal.

    Choose by maximum flow, adjustment range (for example 2 to 22 l/min), thread or mounting (NG6 (CETOP 3), in-line, cartridge) and type of adjustment (fine or normal). For speeds without demanding accuracy, a restrictor may be enough.

    Technical guide: How to choose a hydraulic valve

  • Flow dividers

    DFL and V-EQ flow dividers for splitting flow between two actuators and synchronising their movement. Choose by inlet flow and split ratio.

    The divider takes the pump flow and splits it into two outlets, usually in equal parts, so that two cylinders or two motors move together even with different loads. Many also work in reverse, combining two flows into one.

    A divider is not perfectly exact: with very different loads, the cylinders can get slightly out of step at the end of the stroke. Choose by inlet flow (the divider only works well within its range), split ratio and thread or cavity.

    Technical guide: How to choose a hydraulic valve

  • High-Low Valves

    High-low unloading valves and unloading valves for double-pump or accumulator circuits, from Oleodinamica Marchesini (VABP, VEP), Duplomatic, Argo-Hytos and Eurofluid.

    They are grouped into CETOP high-low and unloading valves, in-line and cartridge versions.

    How high-low unloading works: in a double pump, both pumps combine their flow so the cylinder moves quickly while there is no load. When pressure rises (the cylinder meets resistance), the valve sends the large, low-pressure pump to tank and only the small pump keeps supplying high pressure. The machine stays fast without needing a bigger motor. This is the principle used on log splitters, presses and compactors.

    Unloading valves do something similar with a single pump: they unload it to tank when the circuit reaches pressure, for example when an accumulator is charged, which saves energy and reduces heat. Duplomatic MRQA accumulator charging valves are of this type.

    Choose by switching pressure, the flow of each pump and the thread or mounting.

    Technical guide: How to choose a hydraulic valve

  • End-of-stroke valves

    Mechanically operated end-of-stroke valves, normally open (VF-NA) or normally closed (VF-NC), and V-FCR versions. They cut or divert flow when the cylinder reaches the end of its stroke.

    They are operated by the moving part itself, with no electrical signal, which makes them simple to fit on agricultural machinery and mobile equipment. The range includes Oleodinamica Marchesini models (VF-NA, VF-NC, V-FCR 1T and V-FCR 2T), the 3/8" VFC and the 3/8" V1827 double poppet valve, normally closed. To choose, check whether the valve must be open or closed at rest, the port thread and the flow direction.

    Technical guide: How to choose a hydraulic valve

  • Ball Valves

    High-pressure 2 and 3-way ball valves and 3, 4 and 6-way diverter valves, open or closed centre. For shutting off or diverting flow by hand.

    The RS 2 (2-way) and RS 3 (3-way) ball valves shut off a line or divert it to another outlet. The diverter valves send oil from one inlet to one of several circuits, for example to operate two or more cylinders from the same directional valve port. There is also a 3-way diverter valve rated for 500 bar. All are made by Oleodinamica Marchesini. Check the number of ways, the centre type, the port thread and the working pressure.

    Technical guide: How to choose a hydraulic valve

  • Other Valves

    Valves for specific circuit functions that do not fit the other families: shuttle valves, regenerative circuit valves, rotary unions, cartridge logic elements and more.

    They are grouped into other CETOP valves, in-line and cartridge versions:

    • Shuttle valves: they pass the higher of two pressures, for example to pilot a brake or a load sensing signal from two circuits;
    • Regenerative circuit (VRSP): it adds the oil leaving the cylinder to the oil going in, so the cylinder extends faster with the same pump;
    • Rotary unions: they carry oil to rotating parts;
    • Plough reversing valve and 3-way rotary valves;
    • Cartridge logic elements (NEM, Argo-Hytos), which work as high-flow valves controlled by a pilot signal.

    Brands: Oleodinamica Marchesini, Argo-Hytos, NEM, Eurofluid, Hydac, Badestnost and VOSS.

    To choose, start from the function you need and check the flow, pressure and thread or cavity. The valve selection guide explains the main families. If you are not sure which valve suits your case, describe the circuit to us through the contact form.

    Technical guide: How to choose a hydraulic valve

  • Monoblock and sectional valves

    Directional control valves for operating several cylinders and motors from a single block, and their parts: Badestnost, Duplomatic BLS6, Walvoil and Danfoss PVG.

    There are Badestnost P40, P80 and P120 manually operated monoblock valves, Z50 electro-manual valves, Duplomatic BLS6 sections and parts, Walvoil DLS7 and SD6 sections and covers, and modules and parts for Danfoss PVG16 and PVG32 proportional valves.

    Directional control valves are the usual control on tractors, front loaders, log splitters, cranes and agricultural machinery: each section operates one function, by lever or electrically.

    How to choose a directional control valve:

    • Nominal flow (P40, P80 and P120 indicate roughly 40, 80 and 120 l/min);
    • Number of sections, one per function;
    • Spool type of each section: double acting for double-acting cylinders and motors, single acting, or float (leaves the cylinder free, for blades and implements);
    • Operation (lever, cable, electric) and spool return (spring or detent);
    • Built-in relief valve and connection threads.

    Parts and repair kits are available for P40, P80 and P120, as well as seal kits for PVG. Send us the configuration through the contact form if you need an assembled valve.

    Technical guide: How to choose a hydraulic valve

  • Coils, connectors and electronics

    The electrical side of hydraulic valves: coils that operate solenoid valves, connectors and the control electronics for proportional valves.

    • Coils from Duplomatic, Argo-Hytos, NEM, Danfoss and Vickers, in several voltages;
    • DIN 43650 connectors, with or without LED, and rectifier connectors for running DC coils on an AC supply;
    • Electronics and joysticks: amplifiers, control cards, PWM controllers, control units and Scanreco and Fabercom levers.

    A burnt-out coil is one of the most common faults on a solenoid valve, and it can be replaced without removing the valve. To choose the right coil, check three things on the old one: the voltage and type of current (for example 24 V DC or 230 V AC), the bore (the valve tube it fits on) and the length. The connector must also be the same type.

    On proportional valves, the electronics control the current in the coil and therefore the spool position: the card or amplifier must suit the valve and the command signal (0-10 V, 4-20 mA or PWM).

    Technical guide: How to choose a hydraulic valve

  • NEM - Cartridge valves

    NEM cartridge valves for hydraulic manifold blocks: relief, pressure reducing, check, counterbalance, flow control, solenoid and proportional valves, and accessories.

    The range includes direct-acting and pilot-operated relief valves, pressure reducing valves, check valves, counterbalance (load holding) valves, flow control valves and flow dividers, logic elements, spool and poppet solenoid valves, proportional valves, coils, in-line bodies and seal kits.

    A cartridge valve screws into a standard cavity in the block. A single block can therefore combine several functions in a small space, with no pipework between valves and fewer leak points. It is the usual approach on mini power packs, compact mobile machines and custom manifold blocks.

    How to choose a cartridge:

    • Cavity: for example CAV 08 or CAV 10, 2, 3 or 4-way; the cartridge must match the block cavity;
    • Function and circuit symbol (see the diagram on the product page);
    • Flow and pressure range;
    • On solenoid valves, the coil voltage and connector type.

    The original NEM codes are shown on each version on the product page: search by them. Without a block, in-line bodies let you fit the cartridge directly in the pipework. See also Manifold blocks and subplates.

    Technical guide: How to choose a hydraulic valve

  • Manifold blocks and subplates

    Everything for mounting subplate (CETOP) and cartridge valves on a power pack: subplates, manifold blocks, modular valves, cartridge bodies and accessories, mainly from Eurofluid, Argo-Hytos and NEM.

    How to choose a manifold block: the valve size, such as NG6 (CETOP 3) or NG10 (CETOP 5), the number of stations, how the stations are connected (parallel or series), the threads of P (pressure), T (tank) and outlets A and B, and whether you need a built-in relief valve and a gauge port. Blanking plates cover unused stations.

    Modular valves add functions without changing the pipework: limiting pressure, controlling flow or locking the cylinder with a pilot-operated check valve, stacked underneath the solenoid valve.

    Technical guide: How to choose a hydraulic valve

  • Pressure intensifiers

    ScanWill pressure intensifiers, which multiply circuit pressure by a fixed ratio, in in-line and NG6 (CETOP 3) mounting versions.

    They are used when a cylinder needs more pressure than the pump can deliver, for example on presses and clamping, without changing the pump or the power pack. Outlet flow is lower than inlet flow, in the same proportion as the ratio. Choose by intensification ratio (for example 3.4, 4.0, 5.0 or 7.0), mounting and the outlet pressure you need: models MP-2000-P-7.0, MP-C-3.4 (NG6) and MP-T-P-G are available.

Active filters

Are you an OEM? Reseller? Workshop?

Get special conditions